amp-trap a2y/a6y form 600 / special purpose g 16 ampere catalog ampere catalog ampere catalog ampere catalog ampere catalog rating number rating number rating number rating number rating number 1 a2y1-1 30 a2y30-1 80 a2y80-4 175 a2y175-4 400 a2y400-4 2 a2y2-1 35 a2y35-1 90 a2y90-3 200 a2y200-3 450 a2y450-3 3 a2y3-1 40 a2y40-1 90 a2y90-4 200 a2y200-4 450 a2y450-4 5 A2Y5-1 45 a2y45-1 100 a2y100-3 250 a2y250-3 500 A2Y500-3 6 a2y6-1 50 A2Y50-1 100 a2y100-4 250 a2y250-4 500 A2Y500-4 8 a2y8-1 60 a2y60-1 125 a2y125-3 300 a2y300-3 500 A2Y500-5 10 a2y10-1 70 a2y70-3 125 a2y125-4 300 a2y300-4 600 a2y600-3 15 a2y15-1 70 a2y70-4 150 a2y150-3 350 a2y350-3 600 a2y600-4 20 a2y20-1 70 a2y70-5 150 a2y150-4 350 a2y350-4 600 a2y600-5 25 a2y25-1 80 a2y80-3 175 a2y175-3 400 a2y400-3 a2y ?tandard fuse ampere ratings, catalog numbers ampere catalog ampere catalog ampere catalog ampere catalog rating number rating number rating number rating number 1 a6y1-1 70 a6y70-4 200 a6y200-4 450 a6y450-4 2 a6y2-1 80 a6y80-3 200 a6y200-5 450 a6y450-5 3 a6y3-1 80 a6y80-4 225 a6y225-3 500 a6y500-3 5 a6y5-1 90 a6y90-3 225 a6y225-4 500 a6y500-4 6 a6y6-1 90 a6y90-3 225 a6y225-5 500 a6y500-5 8 a6y8-1 100 a6y100-4 250 a6y250-3 600 a6y600-3 10 a6y10-1 100 a6y100-3 250 a6y250-4 600 a6y600-4 15 a6y15-1 125 a6y125-4 250 a6y250-5 600 a6y600-5 20 a6y20-1 125 a6y125-3 300 a6y300-3 650 a6y650-4 25 a6y25-1 125 a6y125-5 300 a6y300-4 650 a6y650-4 30 a6y30-1 150 a6y150-3 300 a6y300-5 800 a6y800-4 35 a6y35-1 150 a6y150-4 350 a6y350-3 800 a6y800-5 40 a6y40-1 150 a6y150-5 350 a6y350-4 1000 a6y1000-4 45 a6y45-1 175 a6y175-3 400 a6y400-3 1000 a6y1000-5 50 a6y50-1 175 a6y175-4 400 a6y400-4 1200 a6y1200-4 60 a6y60-1 175 a6y175-5 400 a6y400-5 1200 a6y1200-5 70 a6y70-3 200 a6y200-3 450 a6y450-3 - - a6y ?tandard fuse ampere ratings, catalog numbers form 600 fuses ferraz shawmut form 600 fuses were the original current- limiting fuses, pre-dating all the standards. their 500v dc rating (through 600a) is a popular feature for special applications. form 600 fuses provide a high degree of current limitation in ac and dc applications. types 1 and 3 are dimensionally interchangeable with class h and k fuses. types 4 and 5 have unique rejection dimensions and are not interchangeable. type 1, 1-60 amperes class k dimensions ampere inches rating a b a2y - 1-60a 1-30 2 9/16 35-60 3 13/16 a6y - 1-60a 1-30 5 13/16 35-60 5-1/2 1-1/16 ? ac: a2y 1-600a 250vac, 200ka i.r. a6y 1-8a 500vac, 200ka i.r. a6y 10-1200a 600vac, 200ka i.r. ? dc: a2y 1-600a 500vdc, 100ka i.r. a6y 1-8a 500vdc, 100ka i.r. a6y 10-600a 500vdc, 100ka i.r. ratings ? ac: guide no. jfhr2 (1-600a) ? dc tested to ul198l parameters (1-600a) ? ul recognized component approvals ( datasheet : )
amp-trap a2y/a6y form 600 / special purpose g 17 type 5, 650-1200 amperes/hinge disconnect type ?dimensions type 3, 70-600 amperes, class k dimensions ampere inches rating a b c d e j 250 vac/500 vdc - a2y (amp) - 3 70-100 5-7/8 1 1/8 23/32 1-5/8 2-21/32 125-200 7-1/8 1-1/2 3/16 1-1/8 2-3/16 2-25/32 225-400 8-5/8 2 1/4 1-5/8 2-15/16 2-25/32 450-600 10-3/8 2-1/2 1/4 2 3-13/16 2-25/32 600 vac/500 vdc - a6y (amp) - 3 70-100 7-7/8 1 1/8 23/32 2-5/8 2-21/32 110-200 9-5/8 1-1/2 3/16 1-1/8 3-7/16 2-25/32 225-400 11-5/8 2 1/4 1-5/8 4-7/16 2-25/32 450-600 13-3/8 2-1/2 1/4 2 5-5/16 2-25/32 type 4, 70-600 amperes ?dimensions ampere inches rating a b c d e f h j p 250 vac/500 vdc - a2y (amp) - 4 70-100 5-7/8 1 1/8 23/32 1-5/8 4-7/8 13/64 2-21/32 1/2 125-200 7-1/8 1-1/2 3/16 1-1/8 2-3/16 5-3/4 17/64 2-25/32 11/16 225-400 8-5/8 2 1/4 1-5/8 2-15/16 6-3/4 21/64 2-25/32 15/16 450-600 10-3/8 2-1/2 1/4 2 3-13/16 8-1/8 25/64 2-25/32 1-1/8 600 vac/500 vdc - a6y (amp) - 4 70-100 7-7/8 1 1/8 23/32 2-5/8 6-7/8 13/64 2-21/32 1/2 125-200 9-5/8 1-1/2 3/16 1-1/8 3-7/16 8-1/4 17/64 2-25/32 11/16 225-400 11-5/8 2 1/4 1-5/8 4-7/16 9-3/4 21/64 2-25/32 15/16 450-600 13-3/8 2-1/2 1/4 2 5-5/16 11-1/8 25/64 2-25/32 1-1/8 type 4, 650-1200 amperes ?dimensions ampere inches rating a b d e f j k q 600 vac only - a6y (amp) - 4 650-1200 10-1/2 3 2 3-3/8 7-7/8 3-3/4 1-5/16 5/8 type 5, 125-600 amperes/hinge disconnect type ?dimensions ampere inches rating a b c d e f g h j p 600 vac/500 vdc - a6y (amp) - 5 125-200 10-3/4 1-1/2 3/16 1-1/8 3-7/16 8-1/4 3/4 17/64 2-25/32 11/16 225-400 13-1/4 2 1/4 1-5/8 4-7/16 9-3/4 7/8 21/64 2-25/32 15/16 450-600 15-3/16 2-1/2 1/4 2 5-5/16 11-1/8 1 25/64 2-25/32 1 ampere inches rating a b d e f j k q 600 vac only - a6y (amp) - 5 650-1200 12-1/8 3 2 3-3/8 7-7/8 3-3/4 1-5/16 5/8 type 5 125-600a type 5 650-1200a type 4 70-600a type 3 70-600a type 4 650-1200a g
amp-trap a2y/a6y form 600 /special purpose g 18 melting time - current data current in amperes time in seconds available current in rms symmetrical amperes maximum instantaneous peak let-thru amperes peak let-thru current data 1-600 amperes, 250 or 600 volts - types 1, 3 or 5 800-1200 amperes, 600 volts - types 4 or 5 10-600 amperes, 250 or 600 volts 800-1200 amperes, 600 volts only fuse catalog number ampere 250v 600v rating 1 pole 3 pole 1 pole 3 pole 1-30 20306 20308 60306 60308 31-60 20606 20608 60606 60608 61-100 21036 21038 61036 61038 101-200 22001 22003 62001 62003 201-400 24001 24003 64001 64003 401-600 2631 2633 6631 6633 recommended fuse blocks with box connectors for form 600 types 1 & 3 fuses dc capability a variety of pole configurations and termination provisions is available. refer to the fuse holder section of this catalog for details. *consult factory for specifics regarding circuit time constants and dc interrupting rating. catalog no. ampere dc voltage prefix rating rating* a2y 1-600 500 a6y 1-600 500
|